750 Feeder Management Relay
The 750/760 Feeder Management Relay is a digital relay intended for the management and
primary protection of distribution feeders. It can also be used for management and backup
protection of busses, transformers, and power lines. The relay tracks the power system
frequency and adjusts the sampling rate to maintain accuracy at all times.
New in SR750/760:
New Quick-Start manual
Improved Conformal Coating for Harsh (Chemical) Environments
10BaseT Ethernet Port allow for direct connectivity to 10 Mbps Ethernet Local/Wide Area Networks
Expanded sequence of event recorder - 512 time stamped events
Expanded Waveform capture - 2 to 16 events with 4096 to 512 samples of data respectively
View Full Details... View More Info...
New Harsh Environment Conformal Coating option. View More Info...
Features and Benefits
Unique built-in control features - Comprehensive feeder protection plus automatic Transfer Scheme, Under Voltage and Under Frequency auto-restore
Best in class man machine interface (MMI) - Large backlit display with 40 characters to view relay information
and settings in direct sunlight, full numerical keypad, and setpoint navigation keys.
Accurate metering under sever system disturbances - Tracks power system frequency and adjusts sampling rate accordingly
Minimize replacement time - Draw-out construction
Improve uptime of auxiliary equipment - Through I/O monitoring
Reduce troubleshooting time and maintenance costs - IRIG-B time synchronization, event reports, waveform capture, data logger
Simplify testing - Built in simulation features
Cost Effective Access information - Via Modbus RTU and DNP 3.0 Level 2 protocols, through standard RS232, RS485 & RS422 serial ports, and optional Modbus? TCP/IP through embedded Ethernet Port to connect to 10Mbps Ethernet local or wide area networks.
Complete asset monitoring - Analog I/O, Full metering including demand & energy
Follow technology evolution - Flash memory for product field upgrade
Long lasting life - When exposed to chemically corrosive and humid environments with optional conformal coating
Applications
Management and primary protection of distribution feeders
Management and backup protection of busses, transformers and power lines
Reliable Distributed Generation interconnection protection system.
Protection and Control
Complete time, instantaneous & directional phase, neutral, ground and negative sequence overcurrent
Time, instantaneous & directional sensitive ground overcurrent
Voltage restraint overcurrent
Bus phase and line auxiliary undervoltage
Bus phase overvoltage
Neutral overvoltage
Negative sequence voltage
Undervoltage automatic restoration
Bus underfrequency
Underfrequency automatic restoration
Automatic bus transfer
Breaker failure
Manual close control
Cold load pickup control
Power factor control
4 shot recloser
4 setting groups
Syncrocheck - V, f, Hz, & dead-source
20 Programmable logic inputs
Monitoring and Metering
Fault locator, record of last 10
Breaker operation & trip failure
VT Failure
Power factor - two independent stages
Analog input - level and rate
Total breaker arcing current
Event recorder
Oscillography and Data Logger
Metering: V I Hz W var VA PF
Demand: Ia , Ib , Ic , MW, Mvar, MVA
User Interface
Front Panel LEDs, full key pad, and backlit LCD display
RS232, RS485 and RS422 ports - up to 19,200 bps
Ethernet port - 10Mbps
Multiple protocols - ModBus™ RTU, ModBus™ TCP/IP, DNP 3.0 Level 2
Includes EnerVista software